Jul 8, 2006 23:32
17 yrs ago
6 viewers *
French term

doigt gris

French to English Tech/Engineering Automation & Robotics clean room
I can only find a few references to this on google. It seems to be some sort of equipment room off of a clean room (salle blanche). Does anybody know what the correct term is in English? Thanks very much.....

L’équipement permettra l’accès aux commandes et affichages des paramètres en salle blanche et en **doigt gris**.
Proposed translations (English)
2 non-clean room
1 annexe

Discussion

Adam Deutsch (asker) Jul 10, 2006:
I find a certain number of google hits for the term "gray room". However, most of these are from non-English-speaking European countries, so I'm not sure that this is the right term.

Proposed translations

3 hrs
Selected

non-clean room

Well, Adam, you've got the night shift answer here - someone may come up with the quite correct term, but in the meantime...

First of all, I think a "doigt gris" is a room (not a pair of gloves), because there is a picture of one here:

http://www.ultraproprete.com/vert/panorama/zone.asp

They seem to have turned their server off for the night, but there's this text too:

La terminologie utilisée est extrêmement variée pour qualifier les zones à contamination maîtrisée : salles blanches, salles ou blocs stériles, salles microbiologiquement maîtrisées (SMM), salles propres, salles grises, doigts gris, zones à contamination contrôlée (ZCC), zones à atmosphère contrôlée (ZAC), zones à environnement ou empoussièrement contrôlé (ZEC)...

ARTICLE I : Description des locaux: Les locaux sont à usage de laboratoires pour étudiants et chercheurs dans le domaine de la
microélectronique. Ces locaux sont traités en salle propre ;ils forment une salle blanche se décomposant en un sas d’accès, ,une circulation centrale,25 modules ou laboratoires et 2 doigts gris (plan joint).Les surfaces des différentes composantes sont les suivantes :
-Sas d’accès : 15 mètres carrés(module M3). -Circulation centrale :80 mètres carrés. -Modules ou laboratoires :470 mètres carrés.
-Doigts gris :250 mètres carrés(100 mètres carrés + 150 mètres carrés). Hors doigts gris,la classe en ambiance est de 1000 et 100 localement


This text goes a little further and seems to characterize a doigt gris as an intermediary space.

http://72.14.203.104/search?q=cache:eQ6lDtRzW94J:www2.laas.f...

Le deuxième niveau, au premier étage, constituera la salle blanche
proprement dite, il sera doté d’un faux plancher servant à alimenter
les équipements en gaz, électricité, eau désionisée et de refroidissement. L’organisation de la salle est une structure dite en “épi” ou alternent les zones propres à environnement contrôlé et les doigts gris.



This site lists a "non-clean room" as an item in a list. Actually, though, the research on the basis of "clean room" technology seems to indicate that all this involves a gradation. The cleanest of clean rooms only have 1-5 particles of a certain micron size; that measure goes us by orders, and I found descriptions of "doigt gris 1000", which would be less clean than 100 but cleaner than 100,000, etc.

http://72.14.203.104/search?q=cache:5iVwlP0uxwMJ:www.sematec...

Space Summary econmod2
Category
Space Type
(Sq Ft)
CleanRoom
92,980
CMP
Indirect Personnel
4
Dry_Strip_F
2
2,000
Required (Sq Ft)
Non Clean Room
371,920
CleanRoom
(Sq Ft) Non Clean Room
371,920



http://www.nasaexplores.com/show2_912a.php?id=04-050&gl=912

Clean Work Areas are rated by how many particles of contaminants are allowed in the workspace. Most ISS and Space Shuttle flight hardware CWAs are 100K Work Areas. That means that no more than 100,000 particles of .5 microns or larger, are permitted in the area. That may be hard to visualize in terms of a typical nonclean room, but Rachel Kamenetzky, a materials process engineer at KSC says that 100K clean work areas are quite clean. For example, normal walking in average street clothes will produce 10,000,000 particles per minute, with these particles being from 5 microns to 300 microns. The suits worn by people in clean rooms help prevent these particles from entering the clean room environment.

We seem to have gotten everywhere but to an explanation of the expression itself. Like I said, someone may know the exact equivalent. There are also references to procedures for "gowning and gloving" - in passing from a room at one level of clean to a higher level of clean (or vice-versa), you have to change your protective suit. Sometimes, though, you just have to change your gloves.

Assuming on this basis that a doigt gris is a room connected to a salle blanche, it may not be too different from a "salle grise" as mentioned above. And it might be that the doigt gris room is the room where you can still pick up a little dust via the "white glove test" - hence doigt gris.

But I don't seem to find the English sites referring to anything that way. There are clean and non-clean rooms (and even "dirty rooms", but not always in the right connection). There are rooms that have a clean side or end and a dirty side or end. But it appears to me that the particulate level number is what they go by.

Anyway, as they say, HTH.



Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thanks to both of you. The explanations were very helpful. I ended up using "gray room" and told the customer that I didn't think it was the right term."
1 day 1 hr

annexe

On the strength of the following, maybe whatever it is should be called an "annexe" or an "auxiliary room" of some kind:

La température et l’hygrométrie dans la salle blanche générale seront ... Double flux DFI 332 pour la ZONE GRISE DE TRAVAIL et le DOIGT GRIS (2 unités). ...
www.emse.fr/.../prestations_services/ CVC%20Site%20Georges%20Charpak/Descriptif%20Sud%20Travaux%20CVC.pdf

Some people use "yellow" for specific premises associated with clean rooms:

The lab infrastructure has 17 recirculating fans and filter assemblies that circulate air
through the HEPA (High Efficiency Particulate Air) filters at 100 cubic feet/minute.
The filtered air flows from the HEPA filters, in the ceiling, to the floor. Return floor
level louvers allow the air to be taken up into the chase area and flow back up to
the ceiling for re-filtering. In addition, some 5000 cfm of air is removed from the
laboratory (Yellow Room) through process exhaust tubing (primarily from the fume
hoods) and is replaced by filtered air pumped from a makeup air system on the 11th
floor.
[…]
The cleanroom is open 24 hours a day, 7 days a week. Any use of the
cleanroom Yellow Room facilities or instrumentation between the hours of
6PM and 8AM requires the BUDDY SYSTEM; there must be two certified users
present.
[…]
The Buddy System is an arrangement where two people are paired for
mutual safety and assistance. Approved safety glasses are to be worn at
all times in the cleanroom and Yellow Room. The cleanroom policy
requires that when you are in the facility you must be accompanied by
another knowledgeable, trained and certified user. This “buddy” is to be
fully aware of your process and close enough to assist you in case of an
emergency. He or she needs to be in close proximity if you are performing
HF or Piranha etching in the Yellow Room.
[…]
Do not show up with new chemicals in hand expecting instant
approval. In particular, chemicals should not be brought and left
outside the Yellow Room or in the gowning area of the facility awaiting
approval.
http://research.radlab.columbia.edu/clean/cleanroomsafetyman...

Yellow room
Integrated circuits or chips are made in a clean room or yellow room – an area virtually free of dust. The air in the clean room is circulated through filters that capture any particles larger than the filter’s pore size. If common, air-born particles were to land on a wafer during processing, the chips created from that wafer would have defective structures and would not function.
see also: Clean room

http://www.asml.com/asmldotcom/show.do?ctx=8717&year=U-Z [but they are Dutch]

I even found an example where "clean room annexe" is not an annexe (building) housing clean rooms:
The Clean Room Annexe houses important support equipment for the Clean Room Laboratory in a clean room environment together with the group's RF Device ...
nottingham.ac.uk/eee/research/PRFEG_facilities.php
Peer comment(s):

neutral fhdemougins : Hello, a "doigt gris" is the technical side of a clean room. It purpose is to do maintenance task without having to enter the clean room. Thus it is not a clean room at all. I found "chase room" in a drawing but can't get any other reference to confirm.
3151 days
Something went wrong...
Term search