Jun 16, 2008 13:05
15 yrs ago
1 viewer *
French term

ventilations en chicane

French to English Tech/Engineering Architecture
Hi

From a description of the powder store at Brest castle:

"Elle est voûtée de pierre et épaulée de chaque côté par 3 contreforts encadrant des ventilations en chicane."

I imagine these a being slits in a zig-zag pattern but I can't think that will work as a translation!

I found this on a page about powder stores designed by Vauban:
http://www.atelierdesdauphins.com/forts/barraux/poudrier.htm
L’aération est assurée par des évents en chicane pour empêcher tout acte de malveillance".

Event : Orifice ou conduit pour la ventilation d’une casemate

Many thanks for your help!

Discussion

Sandra Petch (asker) Jun 17, 2008:
Tried googling "évents en chicane" and found this engineering dictionary
http://books.google.co.uk/books?id=nhetF1UI7mYC&pg=PA569&lpg...
which gives "baffle plate" for "plaque en chicane." It's a real pain not having a photo or drawing (impossible to make anything out from the photos on the link I gave in the question). I am happy to bow to your knowledge and agree with "baffled". Thank you both for your time and patience (I've chosen Joan's answer as she posted first). Thanks again!
Joan Berglund Jun 17, 2008:
Here are a couple more references, I really think baffled is better.
http://www.granddictionnaire.com/btml/fra/r_motclef/index102...
http://www.camec.com.au/80-Vents & Cowls.htm
Sandra Petch (asker) Jun 17, 2008:
Hello Joan - I can picture exactly what you mean. I'd imagined it differently, that these were slits/vents in the wall, slightly offset from each other (at slightly different heights). There is absolutely nothing on google showing this powder magazine at Brest castle. I'm tempted to play safe and translate as "staggered vents"...
Joan Berglund Jun 17, 2008:
air can flow through, the slats of wood could be called baffles in that instance. I am not sure this is a great explanation, try looking at some examples online
Joan Berglund Jun 17, 2008:
Hi Sandra - I will try to explain, although if you google and find a picture it might be easier to see what I am talking about. Picture a louvered door or window shutter, how the slats of wood overlap each other so you can't see through it very well but
Sandra Petch (asker) Jun 17, 2008:
Sorry, "of the vents" not "of the events"!
Sandra Petch (asker) Jun 17, 2008:
Joan and Liz, you are agreed on this term! I've only ever heard "baffled" meaning "puzzled." I haven't been able to find a definition of the term meaning "staggered." Websters defines the verb baffle as "to break the force or flow" which I suppose is what these vents would do in the event of an explosion. However, I feel "en chicane" refers more to the configuration of the events ("staggered") than their function. Am I being picky?

Proposed translations

+1
6 mins
Selected

baffled ventilation

baffled is a possible defination of en chicane and this did get a few google hits, although only 92, bit it's a starting point
Peer comment(s):

agree Christopher Crockett : Sounds good.
18 mins
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thank you VERY much!"
+3
25 mins

baffled ventilation slots

Historic Buildings - Register Of Historic Buildings
Both stores are lined with brick with a pair of baffled ventilation slots with offset ducts to the exterior of the tower. The west magazine has a heavy ...
www.gov.je/pneapps/web/HistoricBuildingsSearch.aspx?Page=3&... - 89k - Cached - Similar pages

--------------------------------------------------
Note added at 1 day1 min (2008-06-17 13:07:03 GMT)
--------------------------------------------------

If you are thinking of using "staggered vents" perhaps you need to look at English history sites re castles to see if this exists :-)

--------------------------------------------------
Note added at 1 day20 mins (2008-06-17 13:25:46 GMT) Post-grading
--------------------------------------------------

I haven't found it on any site re castles!
Peer comment(s):

agree Christopher Crockett : More precise.
2 hrs
agree Tony M
4 hrs
agree architran : Must be to stop cannonballs going through the windows?
13 hrs
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search