GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
04:33 Jun 1, 2010 |
German to English translations [PRO] Medical - Medical: Instruments / medizinisches Versorgungssystem | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Félicien Sirois United States Local time: 21:10 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 | bonding bolt |
| ||
3 | potential equalization (bar) bolts |
| ||
2 | Connection device for potential equalization conductors |
|
Summary of reference entries provided | |||
---|---|---|---|
FWIW |
|
potential equalization (bar) bolts Explanation: Bolts for mounting/attaching a potential equalization bar (or similar device)? I doubt the bolts themselves have any "equalization" capabilities, but I could be wrong... http://www.hyperline.com/catalog/cabinets/gs-e2-c.shtml Reference: http://www.hyperline.com/catalog/cabinets/gs-e2-c.shtml |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Potentialausgleichsbolzen Connection device for potential equalization conductors Explanation: So übersetzt das jedenfalls DIN auf http://www.beuth.de/langanzeige/DIN 42801/de/835476.html&lim... . So ganz glücklich bin ich aber trotzdem noch nicht. Auf Seite 7 von http://www.mediwar.ch/d/produkte/op/documents/Deckenhangende... werden exakt die als Bolzen bezeichnete Anschlüsse hier als Buchsen aufgeführt - und meiner Meinung nach auch zu Recht. Nicht umsonst vermeidet DIN tunlichst die Verwendung von "bolt". Ich persönlich würde von equipotential bonding terminal sprechen. |
| |
Login to enter a peer comment (or grade) |
bonding bolt Explanation: This is how I would translated this in the USA. This link, for electrical installations, states: "In addition to the Earth Terminal Bars, a reversible internal/external M8 bonding bolt is provided, complying with the sixteenth edition of the IEE Wiring Regulations (BS 7671)." Reference: http://www.cooperet.com/pdf/a56a21eb-ccea-4a6e-a516-404c081b... |
| |
Login to enter a peer comment (or grade) |
1 hr |
Reference: FWIW Reference information: ...Equipment rails, DIN EN 12218, dim. 25x10 mm ...230 V/16 A with control-light and labelling panel as well as 3-pin CEE-sockets 230 V/16 A or 5-pin 400 V/16 A sockets ...Potential equaliser bolts (countersunk), acc. to DIN 42801, Part 1, with green/yellow coloured ring http://www.dameca.dk/files/pdf/op3700e.pdf |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.