Feb 20, 2019 15:50
5 yrs ago
English term

exit enclosures

English to German Tech/Engineering Safety Fire protection
Context:

"According to chapter 7.1.3.2.1 (9) NFPA 101 openings in exit enclosures shall be limited to door assemblies from normally occupied spaces and corridors and door assemblies for egress from the enclosure."

In the context of a fire protection concept for a building prior to a change of use.

* Sentence or paragraph where the term occurs: See above
* Document type: Fire protection concept
* Target audience: Architectural
* Country and dialect (source): US English
* Country and dialect (target): German
Proposed translations (German)
3 +1 Fluchträume
4 Fluchttreppenhäuser

Proposed translations

+1
15 hrs

Fluchträume

Wenn man nach der Definition von «exit enclosures» geht, die u.a. im folgenden Link zu finden ist, sind wohl generell Fluchträume (und nicht nur Treppenhäuser) gemeint.
https://www.everglow.us/pdf/everglow-ibc-ifc-2009-2015-exit-...
Peer comment(s):

disagree gofink : The number of stories connected by the exit enclosure shall include any basements but not any mezzanines. Exit enclosures shall have a fire-resistance rating not less - https://up.codes/s/exit-enclosures
8 hrs
Falls du ganz sicher bist, dass ausschliesslich Treppen gemeint sind. Sonst würde ich eine umfassendere Lösung wählen.
agree Björn Vrooman : Not sure about "-räume," though it's in here: https://shop.vds.de/de/download/f1c5d055d56ab2f8ce566ae4aff8... But the disagreement makes no sense. Both the code(!) and the CSE article say it's about more than stairs, e.g., a tunnel between buildings.
12 hrs
Danke! Fluchtraum heisst in Tunnels definitiv so, aber auch hier https://www.ba-online.info/143-0-Brandschutz- und Evakuierun...
agree Michael Confais (X)
126 days
Something went wrong...
4 hrs

Fluchttreppenhäuser

https://www.slideshare.net/SOJIBSAMS/innovation-technology-o...

see picture 16 of 30: EXIT ENCLOSURES - An exit enclosure shall not be used for any purpose that has the potential to interfere with its use as an exit, if so designated, as an area of refuge.

Das enclosure im Original bezieht sich darauf, dass die Feuertreppe nicht freiliegend außen am Gebäude ist, sondern im Inneren als Fluchtreppenhaus

Fluchttreppenhaus - see https://www.hausjournal.net/fluchttreppenhaus



--------------------------------------------------
Note added at 2 days 5 hrs (2019-02-22 21:00:19 GMT)
--------------------------------------------------

Section 1022 Exit Enclosures

Interior exit stairways and interior exit ramps shall be enclosed with fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 712, or both. Exit enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four stories or more and not less than 1 hour where connecting less than four stories. The number of stories connected by the exit enclosure shall include any basements but not any mezzanines. - see https://up.codes/s/exit-enclosures