GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
16:15 Jun 24, 2015 |
English to Polish translations [PRO] Tech/Engineering - Mechanics / Mech Engineering / gas treatment plant | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Polangmar Poland Local time: 12:22 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 | reset (wskazania/wskaźnika) pierwszego zadziałania/uruchomienia |
|
Summary of reference entries provided | |||
---|---|---|---|
|
reset (wskazania/wskaźnika) pierwszego zadziałania/uruchomienia Explanation: Acknowledge Pushbutton: Momentary alarms will not clear until the alarmed channels have been acknowledged with the ACK pushbutton. This will also reset the first out indication. http://www.predig.com/PD154-158/vfs.php A first-out alarm is an alarm that indicates in some manner that it was the first of a series. This is necessary in circumstances such as an automatic trip or shutdown of equipment, where many alarms will annunciate as a result of a shutdown. The first-out alarm will clearly identify the root cause of the trip or shutdown. https://en.wikipedia.org/wiki/First-out_alarm ...zdalne kasowanie pamięci (LED), pamięć pierwszego zadziałania, pamięć kolejności... http://tinyurl.com/q3zqarg |
| ||
Notes to answerer
| |||
Login to enter a peer comment (or grade) |
3 hrs |
Reference Reference information: There is flashing indication for first alarm only. New subsequent alarms have the same visual as acknowledged alarms. First-out indication is reset and the audible devices silenced when acknowledged - https://goo.gl/zfi6Pd --------- Features Acknowledge Pushbutton: Momentary alarms will not clear until the alarmed channels have been acknowledged with the ACK pushbutton. This will also reset the first out indication. Used in all ISA sequences. Automatic Reset: Acknowledged momentary alarms will clear automatically when the inputs return to normal. The automatic reset is present in all automatic (A) sequences. First-Out Indication: The sequence provides a distinct visual indication for the first channel to alarm. First-Out Reset Pushbutton: Resets the first-out display and assigns the first-out channel to display as a subsequent alarm without any other changes to the sequence. The next alarm input will be a new first-out alarm. Used only in sequence F3A. https://www.dwyer-inst.com/PDF_files/AN2_iom.pdf |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.