transformer protection cell.

French translation: cellule de protection du transformateur (cellule de protection)

10:02 Dec 7, 2020
English to French translations [PRO]
Tech/Engineering - Energy / Power Generation / Solar project
English term or phrase: transformer protection cell.
The step-up substation of the PV installation will be at 20 kV switchgear . The PV field gets to the medium-voltage (MV) busbar through two 20 kV cubicles; the energy output is made by a 20 kV transformer protection cell. The remaining cells are: the output to the Battery Energy Storage System (BESS, three cubicles), one auxiliary services 20/0.4 kV transformer cubicle and a spare one
Neydou
France
Local time: 22:13
French translation:cellule de protection du transformateur (cellule de protection)
Explanation:
Term: transformer protection
Reliability: 3
Term: protection de transformateur
Reliability: 3
https://iate.europa.eu/entry/result/1406725/en-fr-la-mul

2.2.3. BREAKER OUTPUT CELL (TRANSFORMER PROTECTION)
They are metal enclosed, air insulated (busbar) modular cells designed to be used in MV secondary distribution systems and MV / LV substations, indoor spaces.
:
2.2.3.2. List of materials:
• Capacitive voltage indicator …
• Busbar system …
• MV-protection current transformer …
• Overcurrent protection relay …
• Auxiliary relay
• Breaker-earthing switch …
https://www.academia.edu/40045529/Medium_Voltage_Switchgears...

Choix de la cellule de protection du transformateur MT/BT
https://fr.electrical-installation.org/frwiki/Choix_de_la_ce...

DF-P
Cellule de protection ou cellule transformateur avec interrupteur-sectionneur / fusibles combines
https://www.switchgearcompany.eu/fr/isolation-dans-lair-df-2...

Dans la cellule “protection transformateur”, la combinaison interrupteur-fusibles peut être éventuellement remplacée par un disjoncteur.
https://www.cjoint.com/doc/17_02/GBBafyKPKLd_choix-fusibles-...

Un poste HTA/BT est constitué de cellules assurant les fonctions :
o d'arrivée (en nombre variable suivant le type d'alimentation),
o de protection côté HTA et BT,
o de sectionnement côté HTA et BT,
o de mise à la terre et en court-circuit,
o de comptage,
o de transformation (une cellule par transformateur),
o de distribution (tableau général basse tension : TGBT)
:
Cellule de protection HT
Fonction : Une cellule de protection HT assure la protection de la ligne haute tension alimentant le transformateur.
Deux types de protection existent:
• protection par disjoncteur,
• protection par fusibles (autorisée si le courant en ligne côté HTA n’excède pas 45 A)
http://ww2.ac-poitiers.fr/electrotechnique/IMG/pdf/Distribut...
Selected response from:

Johannes Gleim
Local time: 22:13
Grading comment
4 KudoZ points were awarded for this answer



Summary of answers provided
5 +1cellule de protection du transformateur (cellule de protection)
Johannes Gleim


  

Answers


3 hrs   confidence: Answerer confidence 5/5 peer agreement (net): +1
cellule de protection du transformateur (cellule de protection)


Explanation:
Term: transformer protection
Reliability: 3
Term: protection de transformateur
Reliability: 3
https://iate.europa.eu/entry/result/1406725/en-fr-la-mul

2.2.3. BREAKER OUTPUT CELL (TRANSFORMER PROTECTION)
They are metal enclosed, air insulated (busbar) modular cells designed to be used in MV secondary distribution systems and MV / LV substations, indoor spaces.
:
2.2.3.2. List of materials:
• Capacitive voltage indicator …
• Busbar system …
• MV-protection current transformer …
• Overcurrent protection relay …
• Auxiliary relay
• Breaker-earthing switch …
https://www.academia.edu/40045529/Medium_Voltage_Switchgears...

Choix de la cellule de protection du transformateur MT/BT
https://fr.electrical-installation.org/frwiki/Choix_de_la_ce...

DF-P
Cellule de protection ou cellule transformateur avec interrupteur-sectionneur / fusibles combines
https://www.switchgearcompany.eu/fr/isolation-dans-lair-df-2...

Dans la cellule “protection transformateur”, la combinaison interrupteur-fusibles peut être éventuellement remplacée par un disjoncteur.
https://www.cjoint.com/doc/17_02/GBBafyKPKLd_choix-fusibles-...

Un poste HTA/BT est constitué de cellules assurant les fonctions :
o d'arrivée (en nombre variable suivant le type d'alimentation),
o de protection côté HTA et BT,
o de sectionnement côté HTA et BT,
o de mise à la terre et en court-circuit,
o de comptage,
o de transformation (une cellule par transformateur),
o de distribution (tableau général basse tension : TGBT)
:
Cellule de protection HT
Fonction : Une cellule de protection HT assure la protection de la ligne haute tension alimentant le transformateur.
Deux types de protection existent:
• protection par disjoncteur,
• protection par fusibles (autorisée si le courant en ligne côté HTA n’excède pas 45 A)
http://ww2.ac-poitiers.fr/electrotechnique/IMG/pdf/Distribut...

Johannes Gleim
Local time: 22:13
Specializes in field
Native speaker of: German
PRO pts in category: 91

Peer comments on this answer (and responses from the answerer)
agree  Tony M: Though the trouble is, Asker may be looking for 2 different terms to render 'cubicle' and 'cell' — whence the problem... But that's not the issue here: the S/T differentiates them, it's unsafe to render them by the same word in target unless confirmed
11 mins
  -> Thank you. Cubicles and cells may be used synomely used. I remember having designed HT switchgears for HT cells and cubicles. May differ in shape.
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search