Oct 18, 2020 13:50
3 yrs ago
33 viewers *
German term

nicht sicher verwertbar

German to English Medical Medical: Cardiology
Still proofreading the report...

DE: "Transmitraler Fluss nicht sicher verwertbar."

EN: "Transmittal flow not reliably usable."

(Forget "transmittal", that's clear.)

"No reliably usable" sounds awful. But I cannot think of an elegant way of saying this.

Any creative ideas ?

Thanks!"

Discussion

Lirka (asker) Oct 18, 2020:
Good question. It's transthoracic echocardiography :=)
Steffen Walter Oct 18, 2020:
What type of ... ... modality/examination are we talking about here? Is this about imaging?

Proposed translations

+1
45 mins
Selected

transmitral flow velocity measurement gives unreliable values

E/A Ratio - an overview | ScienceDirect Topics
www.sciencedirect.com › topics › e-a-ratio
Apart from the lower mitral inflow E/A ratio and the diastolic myocardial velocity ... Transmitral flow velocity measurements in horses are relatively unreliable and ...

Use and Limitations of E/e' to Assess Left Ventricular Filling ...
www.ncbi.nlm.nih.gov › pmc › articles › PMC3259539
Dec 27, 2011 — However, echocardiographic methods can give us unreliable values under ... Mitral inflow velocity (E) correlates well with LV filling pressure in ...
JH Park · ‎2011 · ‎

Situations where the use of E/e' may be unreliable | Download ...
www.researchgate.net › figure › Situations-where-the-use-...
Mitral inflow velocities obtained by pulsed wave Doppler technique and... Mitral ... (ii) unreliable measurement of E velocity (significant mitral regurgitation), (iii) ...

A Test in Context: E/A and E/e′ to Assess Diastolic ...
www.sciencedirect.com › science › article › pii
Mar 21, 2017 — In this paper, we discuss the physiological basis for transmitral flow ... can be unreliable in the setting of incorrect sample volume placement, ...
SS Mitter · ‎2017 · ‎

Combined influence of ventricular loading and relaxation on ...
www.ahajournals.org › doi › pdf › 01.CIR.78.3.672
The relation of the Doppler transmitral flow velocity profile to left ventricular loading conditions and diastolic properties ... ments of the velocity of blood flow across the mitral valve and, thus ... derivation difficult and unreliable. In the absence of.
CY Choong · ‎1988 · ‎

Methods and Reliability of Tissue Doppler Imaging for ...
onlinelibrary.wiley.com › doi › full
May 19, 2009 — Doppler‐derived transmitral flow velocities are commonly used in humans and small animals for assessment of diastolic LV function and filling ...
CC Schwarzwald · ‎2009 · ‎
Peer comment(s):

agree philgoddard : I think the next two answers are effectively the same as yours.
1 day 2 hrs
Thanks, Phil, also for your peer comment!
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thank you!"
+1
47 mins

could not be reliably evaluated

That's what I would say, although my answer could not be reliably evaluated...
Note from asker:
Thank you, David, I awarded points to andres-larsen b/c his answer came first and was actually correct, although I prefer your version. :=)
Peer comment(s):

agree Steffen Walter : "Nicht sicher verwertbar" is the same as "nicht sicher beurteilbar", in my view. In other words, an unclear/inconclusive finding/result re. the transmitral flow profile/velocity.
8 mins
Something went wrong...
+3
59 mins

unclear/inconclusive

unclear/inconclusive finding/result regarding the transmitral flow profile/velocity

--------------------------------------------------
Note added at 59 mins (2020-10-18 14:50:53 GMT)
--------------------------------------------------

"Nicht sicher verwertbar" is the same as "nicht sicher beurteilbar", in my view.
Note from asker:
I awarded points to andres-larsen for his answer came first and was actually correct, but thank you for clarifying that verwertbar=beurteilbar in this case. This is what I wasn't sure about.
Peer comment(s):

agree Barbara Schmidt, M.A. (X) : agree - exactly
1 hr
agree Anne Schulz
1 hr
agree David Hollywood : meine ich auch Steffen...kurz und bündig
12 hrs
Something went wrong...
-1
7 hrs

unamenable to safe & secure use

Remember the adjective of un/amenable: file mentally or enter in a glossary for 'safe & secure future use and ref.' - or, as my Scottish acquaintance from Edinburgh used to exhort me: 'stamp that word on yer .... for'ead !'

Illegally obtained evidence in Germany-speaking countries is classed as 'nicht vewertbar' - unusable but may be if actually admitted.
Example sentence:

Case report An ingested mobile phone in the stomach may not be amenable to safe endoscopic removal using current therapeutic devices: A case report

Peer comment(s):

disagree Steffen Walter : This is not about "use" - please note the medical context and jargon.
8 hrs
neutral philgoddard : I disagree with your answer, but I like your example sentence.
19 hrs
Something went wrong...
3 days 22 hrs

not enough/reliable /not reliably measurable (bu an echochardiography machine)

More context is needed. As it is, I would think the text may be referring to the fact that the blood flow through the mitral valve could not be reliably measured (through ultrasound). Or else, it could not be enough for the needs of the cardiovascular system (as per disturbances on the aortal valve, such as mitral stenosis and/or reflux). Or both.

--------------------------------------------------
Note added at 3 days 22 hrs (2020-10-22 11:55:25 GMT) Post-grading
--------------------------------------------------

Sorry, typo: "not reliably measurable (BY an echocardiography machine)
Example sentence:

Reste, Abfälle [noch zu etwas] verwerten etwas ist noch zu verwerten.

Der Körper verwertet die zugeführte Nahrung (gewinnt aus ihr die für ihn nötigen Nährstoffe)

Something went wrong...